Water Leak Detection
Our Primary Products for Leak Detection are Manufactured by RLE, the Leader in General Facility Monitoring and Leak Detection for Critical Facilities
- Water Leak Detection - Three basic types exist:
- Spot detector which looks for water at a specific spot
- Zone Cable detector which looks for water at any spot along a cable and reports the cable is wet somewhere
- Distance Read Cable which looks for water at any spot along a cable and reports specifically where on the cable it has found water.
- A complete system is composed of detecting devices (spot type and/or cable type) and a control/alarm module that notifies of the leak. Some typical full systems are shown at the bottom of this web page.
- Please note we realize there are many configurations of water detection possible and some of our customers may be unsure what to order for their particular need. Please feel free to add items to your shopping cart and print a copy of the cart to forward by email or fax to us and do not complete the purchase. We can then follow up with you to ensure the correct parts are being included. You may then return to a web order or provide your credit card and shipping information by phone to complete an order. Alternately please use the complete systems section at the end of this page to order a system.
-
-

- Input power can be 24V AC or DC,
- Output is a form C non - powerd contact (NO,C,NC)
- Use the Form C contacts to report to our alarm panels, building managemant systems or any monitor that can read contact closures. (Contacts rated 1A at 24V, 0.5 amps at 120V.)
- When powered by AC an alarm condition is latched until power is removed and reset to ensure alarm is not missed if it came and cleared.
- Physical dimensions: 1.55"w x 2"h x 1"d, 7 ounces, comes with 14' cable as shown above for interface to alarm panels. Cable may be extended in the field.
- Power supply is ordered separately, if needed.
- Manual Switch not included.
-

- Typical Connection Shown Above to a Falcon Panel (purchased separately)
- Powered by the Falcon, as shown alarm will latch until power is removed and reset by either powering Falcon on and off, removing terminal block or wiring a reset switch as shown in diagram with #104609 above.
- Physical dimensions: 1.55"w x 2"h x 1"d, 4 ounces, comes with 14' cable as shown above for interface to alarm panels. Cable may be extended in the field.
-

- Typical Connection Shown Above to a LD1000 Panel (purchased separately)
- Powered by the LD Panel, If DC powered alarm will latch until power is removed and reset by either powering LD Panel on and off, removing green wire or wiring a reset switch as shown in diagram with #104609 above.
- Physical dimensions: 1.55"w x 2"h x 1"d, 5 ounces, comes with 14' cable as shown above for interface to alarm panels. Cable may be extended in the field.
-
- Water Leak Detection Cable, Zone and Direct Read
- You'll need the cable, a Leader/EOL resistor Kit and Hold Down Clips

- Water Detection Cable can be used in zone or direct read systems. The cable is the same. It is the attached controller that determines if it is a zone or direct read system. Cable has specific connector on each end for attachment to previous and next components. At the final end of cable run and end of line resistor plugs in. Often installations will be composed of multiple shorter lengths of cable to ease installation and smaller potential replacement if a cable ever becomes damaged or unuseable for any reason. Thus a 100' run may be (1) 100' cable, (2) 50' cables or (4) 25' cables. Custom lengths are also available. Cables are Plenum Rated CL2P. Standard lengths are:

- Each individual run of a water detection cable system requires an end of line resistor at the far end and a leader cable to allow connection of the starting end for the connection to a control/alarm panel. This comes as a kit with a 15' leader cable
and the end of line resistor.

- The cable is typically held close to the floor or surface via specific hold down clips. Clips are spaced abouut 3 to 4 feet apart and closer where turns are made.
- Control / Alarm Panels
(6 listings)
-
- Adjustable Sensitivity
- Outputs for leak detected and cable fault
- Includes Leader/ EOL Resistor Kit
- Easy install, small 2.7"w x 4.4"h x 1.1"d, 3 ounces
- Use with Water Detection Cable of lengths to 300' (above) or spot detector #104612
- Requires 5 VDC power: 120V Wall Power Plug Adaptor #105672 is optional power supply normally selected for this.
-

- Audible Alarm
- Adjustable Sensitivity
- Outputs for leak detected and cable fault
- Includes Leader/ EOL Resistor Kit
- Easy install, 4.2"w x 5.5"h x 2.3"d, 2 pounds
- Use with Water Detection Cable of lengths to 1000' (above) or spot detector #104612
- Requires 24 V AC or DC power: 120V Wall Power Plug Adaptor #105156 is optional AC power supply normally selected for this.
-

- Audible Alarm
- Adjustable Sensitivity
- Form C (NO,C,NC) Outputs for each zone / input plus overall summary alarm output
- Inputs may be configured to monitor equipment alarms such as UPS, generators, HVAC units or any dry contact alarm point
- Requires Leader/ EOL Resistor Kit for each Leak Detection Cable Zone
- Modbus RTU output (EIA-485) for integration to BMS Systems
- Easy install, 10.5"w x 8"h x 2"d, 4 pounds
- Use with Water Detection Cable of lengths to 1000' (above) for each zone or spot detector #104612
- Requires 24 V AC or DC power: 120V Wall Power Plug Adaptor #105156 is optional AC power supply normally selected for this.
-

- Visual Alarm indication, no audible
- Notifies where on cable leak has been found, i.e at 76 foot point.
- Includes Leader/ EOL Resistor Kit
- Easy install, 10.5"w x 8"h x 2"d, 4 pounds
- Use with Water Detection Cable of lengths to 1500' (above)
- Requires 24 V AC or DC power: 120V Wall Power Plug Adaptor #105156 is optional AC power supply normally selected for this.
- Optional Framed Reference Wall Map to cross reference footage length along cable to assist pinpointing leak
- Designed to integrate with LD2100 and LD5100
-
-

- On Screen HTML Mapping
-

- Visual and AudibleAlarm indication
- 4 email recipients allowed, alarm and return emails sent
- Notifies where on cable leak has been found, i.e at 76 foot point.
- Includes Leader/ EOL Resistor Kit
- Easy install, 10.5"w x 8"h x 2"d, 4 pounds
- Use with Water Detection Cable of lengths to 5000' (above) and separated in up to 32 virtual or physical zones
- Requires 24 V AC or DC power: 120V Wall Power Plug Adaptor #105156 is optional AC power supply normally selected for this.
- Optional Framed Reference Wall Map to cross reference footage length along cable to assist pinpointing leak
-
-

- Visual and AudibleAlarm indication
- Notifies where on cable leak has been found, i.e at 76 foot point.
- Includes Leader/ EOL Resistor Kit
- Easy install, 12.5"w x 10"h x 3.3"d, 10 pounds
- Use with Water Detection Cable of lengths to 5000' (above) and separated in up to 12 virtual or physical zones
- 2 Form C Leak Detected Outputs, 2 Form C Cable Break Outputs, 4-20 mA Analog Output
- Logs last 500 events, trends cable current level for last 288 days
- 120/ 240VAC power supply included.
- Optional Framed Reference Wall Map to cross reference footage length along cable to assist pinpointing leak
-
Typical System Configurations (suggested bill of materials) Note: All of these configurations below can be used to send alarm signals to a separate building or facility monitoring system such as a Falcon Series. If you want more detail on a part number listed just do a Ctrl-F in most browsers and type in the part number to find it elsewhere on this webpage.
Water on floor at one spot - visual alarm only (also works for drain pans under HVAC units)
Water on floor at one spot - visual and audible alarm (also works for drain pans under HVAC units)
Water on floor in a single area/zone - visual alarm only (often used for under computer raised floors)
- Water Detection Cable length as desired for area to be monitored (max 300')
- Hold Down Clips, pick package size desired, usually base upon cable length divided by 3
-
Water on floor in a single area/zone - visual and audible alarm (often used for under computer raised floors)
- Water Detection Cable length as desired for area to be monitored (max 300')
- Hold Down Clips, pick package size desired, usually base upon cable length divided by 3
Water on floor at 1 to 6 multiple locations (spots or zones)- visual and audible alarm
- Pick up to 6 total water detection devices, which can be a mixture of spot detectors and cable detectors
- Water Detection Cable length as desired for area to be monitored (max 300')
- Hold Down Clips, pick package size desired, usually base upon cable length divided by 3
Water at specific spot along a cable run - visual alarm, web and SNMP interface
- Water Detection Cable length for area to be monitored (max 1500') Cable is a single run.
- Hold Down Clips, pick package size desired, usually base upon cable length divided by 3
Water at specific spot along a cable run - visual and audible alarm, email notification, web and SNMP interface. Includes network accessed html mapping.
- Water Detection Cable length for area to be monitored (max 5000') Cable is a single run but may be broken into multiple zones (contact us for details)
- Hold Down Clips, pick package size desired, usually base upon cable length divided by 3
Water at specific spot along a cable run - visual and audible alarm, unit mounted LCD Interface
- Water Detection Cable length for area to be monitored (max 5000') Cable is a single run but may be broken into multiple zones (contact us for details)
- Hold Down Clips, pick package size desired, usually base upon cable length divided by 3